120V 25AMP Automatic Transfer Switch for Power Sydtem
-
Price:
Negotiable
- minimum:
- Total supply:
-
Delivery term:
The date of payment from buyers deliver within days
-
seat:
Guangdong
-
Validity to:
Long-term effective
-
Last update:
2017-10-11 04:06
-
Browse the number:
199
Company Profile
Dongguan Ouxiper Electronic Co., Ltd.By certification [File Integrity]
Contact:Mr. Clark(Mr.)
Email:
Telephone:
Phone:
Area:Guangdong
Address:Guangdong
Website: http://ouxiper.china-mdf.com/
Product Details
MSTS is a kind of switch of fast load transfer, its minimum transfer time is 3.2ms and it is applicable to the real load transfer in the same phase and the different phases. Except the fast load transfer, the many sets of MSTS can be connected together to synthesis the n+1=1 circuit output, which can enhance the safety of the power supply. MSTS owns the small volume and friendly human and computer interface leaves you a smart and harmonious feeling.
Product Advantages:
NO.1 The first and the back-up power supply can be set up. There is no power confilict
NO.2 Fast load transfer:
LSTS can reach the fastest transfer (3.2ms) in the same phase and different phase
NO.3 Switch can switch automatically. And hand operation is approved, too
NO.4 The two way power supply can be input the LSTS in the same phase and different phase,share the zero-fire or not
NO.5 Protection function:
When the overrun protection of output current is 110%, the impact capability will input the over current in 4: 1 and conducts the lightning protection
NO.6 LCD and LED can display the machine working status
NO.7 Fault alarm:
When there is something wrong with the environmental electric quantity and output electric quantity, the equipment will start the audile and visual alarm and and the alarm will stop automatically 90 seconds later
NO.8 Dry Contact Singnal and Rs232 make it easier for user to check the working condition, like the input of electric,the output of current and working information, and so on
NO.9 There is a module of Lightening Protection ( C level ) for power supply.
NO.10 LSTS can check the overvoltage,undervoltage,power down constantly
NO.11 Output socket are industrial IEC-C13, IEC-C19 ,or select other socket(socket is flexible)
:
Product Advantages:
NO.1 The first and the back-up power supply can be set up. There is no power confilict
NO.2 Fast load transfer:
LSTS can reach the fastest transfer (3.2ms) in the same phase and different phase
NO.3 Switch can switch automatically. And hand operation is approved, too
NO.4 The two way power supply can be input the LSTS in the same phase and different phase,share the zero-fire or not
NO.5 Protection function:
When the overrun protection of output current is 110%, the impact capability will input the over current in 4: 1 and conducts the lightning protection
NO.6 LCD and LED can display the machine working status
NO.7 Fault alarm:
When there is something wrong with the environmental electric quantity and output electric quantity, the equipment will start the audile and visual alarm and and the alarm will stop automatically 90 seconds later
NO.8 Dry Contact Singnal and Rs232 make it easier for user to check the working condition, like the input of electric,the output of current and working information, and so on
NO.9 There is a module of Lightening Protection ( C level ) for power supply.
NO.10 LSTS can check the overvoltage,undervoltage,power down constantly
NO.11 Output socket are industrial IEC-C13, IEC-C19 ,or select other socket(socket is flexible)
Main Technical Parameters: |
|
|
|
|
||
Model | MSTS-16A | MSTS-25A | MSTS-30A | |||
Standard Volume | 3.5KW | 5.5KW | 6.6KW | |||
Rated Current | 16A | 25A | 30A | |||
Switch Time | ≤5ms | |||||
Output Interface | IEC C13,C19 | IEC C19 | IEC C19 | |||
Priority | Automatic setting | |||||
Input | Scope of input voltage of M1circuit | 110VAC/240V | ||||
Scope of input voltage of M2 circuit | 110VAC/240V | |||||
Scope of input frequency | 50HZ-60HZ | |||||
Power environment | Same phase and different phases | |||||
Output | Scope of output voltage | 110VAC/240V | ||||
Output over current | 110% | |||||
Output efficiency | ≥98% | |||||
Management | Status display | Display of LCD electric quantity parameters, display of LED status | ||||
Interface management | RS232 interface/interface of dry contact | |||||
Software | X | |||||
Protection | Power surge protection | Input M1/input M2 | ||||
Communication surge protection | RS232 interface/interface of dry contact | |||||
Overload short circuit protection | Over current short circuit protector | |||||
Standard Recognition |
Design and production | ISO9001:2000 | ||||
Safety certificate | EN50091-2,IEC60950 | |||||
Electromagnetic compatibility | EN50091-2,EN61000-3-2,EN6000-4-2/-3/-4 | |||||
Environment | Environmental temperature | -30°C----+60°C | ||||
Environmental humidity | 0%-90% | |||||
Physical property |
Size of machine | 1U×19 Inches(482×249×44.5mm) | ||||
Size of package | 540×360×110mm |
: